32/38 Engine Driven Generator

Speed: Low Speed
Cooling Cylinder: Water-Cooled
Fuel: Hfo
Number of Strokes: Four-Stroke
Number of Cylinders: 8-Cylinder
Rated Electrical Power: 2000kw
Customization:
Gold Member Since 2017

Suppliers with verified business licenses

Zhejiang, China
to see all verified strength labels (7)

Basic Info.

Model NO.
2000GF generator set
Engine Capacity
2206kw
Fuel Consumption
519 L/H
Transport Package
Wooden Case
Specification
8550*2663*3348*2200 mm
Trademark
Ningbo diesel
Origin
Ningbo
Production Capacity
3000 Piecews/Year

Product Description

Main Specification
Generator Model  1500GF 2000GF 2200GF 2500GF 3000GF
Rated Electrical Power (kW) 1500 2000 2200 2500 3000
Engine Model GN6320ZD14 GN8320ZD GN8320ZD2 GN8320ZD4 DN8320ZD28
Bore x Stroke (mm) 320x380
Engine Type  4-Stroke, Inline, Direct Injection,Turbocharged, Intercooled
Engine Capacity (kW) 1618 2206 2500 2795 3310
Engine Rev. (rpm) 600 600 600 600 50Hz@750
60Hz@720
Fuel Consumption (L/h) 385.2 519 571 648.8 778.6
 
Note: All engine rating data based on ISO 3046/1;
Reference conditions: Ambient temperature 25ºC, Total Barometric Pressure:100kPa, Relative humidity 30%, Intercooler coolant inlet temperature 25 ºC;
Fuel characteristics: Related density: 0.84±0.005, Lower heat value:42700kj/kg, Consumption tolerance: +5%;
Power: An overload of 10% is permitted for one hour in every twelve hours of operation

Characteristics:
Meet with: ISO8528, IEC60034, ISO3046; 
Marine medium speed engine driven, HFO burning; 
Brushless self excited alternator with AVR; Low speed with power margin and fuel flexibility;
Continuous running, low noise, long TBO, low operating cost.
Electrical Performance
Voltage Voltage no load adjustment range % 95~105
Voltage fluctuation rate % ±1
Stable voltage regulating rate % ±2.5
Transient voltage regulating rate % ±20~-15
Stabilizing time s 1
Alternator Excitation method   Brushless AVR
Frequency Stable frequency (rev.) regulating rate % 5
Frequency (rev.) fluctuation rate % ±0.5
Transient frequency regulating rate % ±10
Stabilizing time s < 5
Frequency regulating method   Auto / Manual
Protection Over speed   115% Nr   A, T, S   Reverse P.   -9.6% Pn   A, T
LO. P 0.25MPa A, 0.15MPa T,S   Over current  130% In     A, T
FW T. 90ºC A, 95ºC T,S   Over voltage 120% Vn     A, T
LO. T 90ºC A              Over load   110% In    A
 















 
 
 
 